| □It can be used inindoor system of 50HZ and rated voltage of 3.6KV,7.2Kv,12KV,24KV,40.5KV:Used together with other switch facilities such as loading swithes,vacuum contactors,it can protecti electric transformers and other electric facilities against overloading or circuit break.It is also a necessary accessory for high-voltage switch box,circular circuitcabinet,high Low voltage top-loading transformer substation. |
| ◆Type instruction |
 |
| ◆Basic parameters |
| Type |
Counterpart |
Rated voltage |
Rated current of the fuse (A) |
Rated current of the fuselink (A) |
| XRNT-12 |
SDLAJ |
12 |
40 |
3.15、6.3、10、16、20、25、31.5、40 |
| XRNT-12 |
SFLAJ |
12 |
100 |
50、63、71、80、100 、(125) |
| XRNT-12 |
SKLAJ |
12 |
125 |
125、160、200、250 |
| XRNT-24 |
|
24 |
200 |
3.15、6.3、10、16、20、25、31.5、40 50、63、80、100 、125、160、200 |
| XRNT-40.5 |
|
40.5 |
125 |
3.15、6.3、10、16、20、25、31.5、40 50、63、80、100、125 | |
| ◆Installation Dimensios |
| Chat1/a link XRNT□-12Kv Chat2/a link XRNT□-24Kv |
 |
| Chat3/a link XRNT□-40.5Kv Chat4/b link(12KV) |
 |
Inserting type fuse Insertingfypefuse XRNT口-24Kv XRNT口-40.5Kv |
 |
| 3.6-40.5KV型熔断器(插入式) |
 |
| ◆Tachnique data |
| Type |
UN(KV) |
IN(A) |
D×L(mm) |
Rated break current (KA) |
| XRNT1 |
3.6/7.2 |
6.3 |
Φ51×192标准尺寸 |
63 |
| 10 |
| 16 |
| 20 |
| 25 |
| 31.5 |
| 40 |
| 50 |
| 63 |
Φ76×192标准尺寸 |
| 80 |
| 100 |
| 125 |
| 160 |
Φ88×192标准尺寸 |
| *200 |
50 |
| *250 |
| 6.3 |
Φ51×292标准尺寸 |
63 |
| 10 |
| 16 |
| 20 |
| 25 |
| 31.5 |
| 40 |
| 50 |
| 63 |
Φ76×292标准尺寸 |
| 80 |
| 100 |
| 125 |
| 160 |
Φ88×292标准尺寸 |
50 |
| *200 |
| *250 |
| *315 |
| *355 |
| 100 |
Φ76×442 |
63 |
| 125 |
| 160 |
Φ88×442 |
| *200 |
50 |
| *250 |
| *315 |
| *355 |
| *400 |
| *500 | |
| |
| Type |
N(KV) |
IN(A) |
D×L(mm) |
额定开断电流(KA) |
国外参考型号 |
| XRNT |
6/12 |
6.3 |
Φ51×192 |
63 |
SDLAJ |
| 10 |
| 16 |
| 20 |
Φ76×192 |
| 25 |
| 31.5 |
| 40 |
| 2 |
Φ51×292标准尺寸 |
| 3.15 |
| 6.3 |
| 10 |
| 20 |
| 31.5 |
| 40 |
| 50 |
Φ63×292 Φ63×292 标准尺寸 |
SFLAJ |
| 63 |
| 80 |
| 100 |
| 125 |
SKLAJ |
| *160 |
Φ88×292 标准尺寸 |
50 |
|
| *200 |
| 6.3 |
Φ51×442 |
63 |
高压中置柜专用高压限流熔断器 |
| 10 |
| 16 |
| 20 |
| 25 |
| 31.5 |
| 40 |
| 50 |
Φ76×442 标准尺寸 |
| 63 |
| 80 |
| 100 |
| 125 |
| 160 |
Φ88×442 标准尺寸 |
| *200 |
50 |
| *250 |
| 100 |
Φ76×537 |
63 |
|
| 125 |
| 160 |
| *200 |
50 |
| *250 |
Φ88×537 |
| *315 | |
| (*)请注意降容使用,可参看熔断器的合理选用。 |
| Type |
UN(KV) |
IN(A) |
D×L(mm) |
Rated break current(KA) |
| XRNT1 |
24 |
6.3 |
Φ51×442标准尺寸 |
|
| 10 |
| 16 |
63 |
| 20 |
| 25 |
| 31.5 |
| 40 |
| 50 |
Φ76×442标准尺寸 |
| 63 |
| 80 |
| 100 |
| 125 |
Φ88×442标准尺寸 |
40 |
| 160 |
| 200 |
| 6.3 |
Φ51×537 |
63 |
| 10 |
| 16 |
| 20 |
| 25 |
| 31.5 |
| 40 |
| 50 |
Φ76×537 |
| 63 |
| 80 |
| 100 |
| 125 |
Φ88×537 |
40 |
| 160 |
31.5 |
| *200 |
| 6.3 |
Φ51×442 |
| 10 |
| 16 |
| 6.3 |
Φ51×537 标准尺寸 |
40 |
| 10 |
| 16 |
| 20 |
| 25 |
Φ76×537 标准尺寸 |
| 31.5 |
| 40 |
| 50 |
Φ88×537 标准尺寸 |
| 63 |
| 80 |
| 160 | |
| (*)请注意降容使用,可参看熔断器的合理选用。 |
| KVA |
变压器初级电压 7.2KV |
| 熔断器额定电压KV |
熔断器额定电流A |
| 100 |
7.2 |
20 |
| 125 |
20 |
| 160 |
25 |
| 200 |
31.5 |
| 250 |
40 |
| 300/315 |
50 |
| 400 |
71 |
| 500 |
80 |
| 630 |
100 |
| 750/800 |
140 |
| 1000 |
160 |
| 1250 |
200 | |
| |
| 变压器容量KVA |
变压器初级电压 12KV |
| 熔断器额定电压KV |
熔断器额定电流A |
| 100 |
12 |
16 |
| 125 |
16 |
| 160 |
16 |
| 200 |
20 |
| 250 |
25 |
| 300/315 |
31.5 |
| 400 |
40 |
| 500 |
50 |
| 630 |
63 |
| 750/800 |
80 |
| 1000 |
100 |
| 1250 |
125 |
| 1500/1600 |
160 |
| 2000 |
200 | |
| 变压器容量KVA |
变压器初级电压 24KV |
| 熔断器额定电压KV |
熔断器额定电流A |
| 100 |
24 |
6.3 |
| 125 |
6.3 |
| 160 |
10 |
| 200 |
10 |
| 250 |
16 |
| 300/315 |
16 |
| 400 |
20 |
| 500 |
25 |
| 630 |
31.5 |
| 750/800 |
40 |
| 1000 |
50 |
| 1250 |
63 |
| 1500/1600 |
80 |
| 2000 |
100 |
| 2500 |
125 |
| 3150 |
160 |
| 4000 |
200 | |
| |
| 变压器容量KVA |
变压器初级电压 40.5KV |
| 熔断器额定电压KV |
熔断器额定电流A |
| 50 |
35 |
2 |
| 100 |
3.15 |
| 125 |
5 |
| 160 |
5-6.3 |
| 200 |
6.3 |
| 250 |
8-10 |
| 315 |
10-12 |
| 400 |
12-16 |
| 500 |
16 |
| 630 |
20-25 |
| 800 |
25-31.5 |
| 1000 |
31.5-40 |
| 1250 |
40-50 |
| 1600 |
50 |
| 2000 |
63 | |
 |
XPNT1-12KV/6.3A~200A XRNT口-3.6KV~7.2KV/6.3A~315A |
 |
| 图2 SDL、SFL、SSFL限流特性 |
 |
| 图3 SDL、SFL、SKL l2t特性 |
 |
| 图4 XRNT1-24KV限流特性 |
 |
| 图5时间-电流特性 |
 |
| 图6 XRNT 40.5KV时间-电流特性曲线 |
| □These devices are suitable for a.c.50Hz,rated voltage 3.6kv.7.2kv,12kv power systems and they canbe used with other protection electric apparatus(such asload switch,vacuum contactor)as portectionof trans for mer power equipment against overloads or short-circuits. |
| Type |
 |
| 基本参数 |
| 熔断器的基本参数见表1、表2 |
| 主要技术数据 |
(1)熔断器应能开断最小开断电流l3至最大开断电流l1之间的任何故障电流。l3电流约为4倍额定电流 (2)时间一电流特性如图1,最小开断电流l3以上部分为虚线 |
| 外形及安装尺寸 |
| 熔断器的外形及安装尺寸如图2、图3、图4 |
| 表1 |
| Type |
额定电压 A |
熔断件额定电流 A |
主要参数mm |
额定最大开断电流kA |
外形尺寸 |
| 长度 |
直径 |
| BFY口-40.5KV/口A |
40.5 |
3.15、6.3、10、16、20、25、31.5、40、50 |
650 |
ρ76 |
31.5 |
插入式见图2 |
| 母线式见图3 |
| XRNT口-40.5 KV/口A -31.5-1 |
3.15、6.3、10、16、20、 25、31.5、40、50 |
见图4 | |
| 根据用户要求提供的非标形式 |
 |
| □These devices are suitable for a.c.50Hz,rated voltage 3.6kv.7.2kv,12kv power systems and they canbe used with other protection electric apparatus(such asload switch,vacuum contactor)as portectionof trans for mer power equipment against overloads or short-circuits. |
| 型号 |
 |
| 基本参数 |
| 熔断器的基本参数见表1 |
| 表1 |
| Type |
等同型号 |
额定电压 kV |
熔断件额定电流A |
主要参数mm |
额定最大开断电流kA |
| C |
ΦD |
| XRNT□-3.6 |
ADF*□ |
3.6 |
6.3、10、16、20、25、31.5、40 |
254 |
Φ51 |
50 |
| ADG*□ |
6.3、10、16、20、25、31.5、40、 50、63、80、100 |
359 |
| XRNT□-7.2 |
ADF*□ |
7.2 |
6.3、10、16、20、25、31.5、40、 50、63 |
254 |
| BDG*□ |
6.3、10、16、20、25、31.5、40、 50、63、80 |
359 |
| AFF*□ |
80、100 |
254 |
Φ76 |
| BFG*□ |
100 |
359 |
| BKG*□ |
125、140、160 |
| XRNT□-12 |
BDG*□ |
12 |
6.3、10、16、20、22.4、25、31.5、 35.5、40、45、50 |
359 |
Φ51 |
| XRNT□-12 |
BFG*□ |
12 |
56、63、71、80、90、100 |
359 |
Φ76 |
| AKG*□ |
112、125 |
| AKG*□ |
160、200 |
Φ88 | |
|
注:1、以上为单管额定参数,可根据用户需要采用固定结构将熔断器并联,以得到高的额定电流值; 2、*代表撞击器的不同种类。 |
| 主要技术数据 |
(3)熔断器应能开断最小开断电流l3至额定最大开断电流之间的任何故障电流。 额定电流125A以下熔断件不包括125A l3电流约为4倍额定电流。 额定电流125A以上包括125A 13电流约为7倍额定电流。 (4)时间-电流特性如图1,最小开断电流以上部分为虚线。 |
| 外形及安装尺寸 |
| 熔断器的外形及安装尺寸如图2~图8 |
|
熔断器的选用 |
| 用于变压器初级端熔断器的一般选用法则如表2 |
| 表2 |
| 变压器容量kVA |
变压器初级电压 3.6kV |
| 熔断器额定电压kV |
熔断器额定电流A |
| 100 |
3.6 |
31.5 |
| 125 |
40 |
| 160 |
50 |
| 200 |
63 |
| 250 |
80 |
| 300/315 |
90 | |
| |
| 变压器容量 kVA |
变压器初级电压 7.2kV |
| 熔断器额定电压 kV |
熔断器额定电流 A |
| 100 |
7.2 |
20 |
| 125 |
20 |
| 160 |
25 |
| 200 |
31.5 |
| 250 |
40 |
| 300/315 |
50 |
| 400 |
71 |
| 500 |
80 |
| 630 |
100 |
| 750/800 |
140 |
| 1000 |
160 | |
| 变压器容量kVA |
变压器初级电压 12kV |
| 熔断器额定电压 kV |
熔断器额定电流 A |
| 100 |
12 |
16 |
| 125 |
16 |
| 160 |
16 |
| 200 |
20 |
| 250 |
25 |
| 300/315 |
31.5 |
| 400 |
40 |
| 500 |
50 |
| 630 |
63 |
| 750/800 |
71 |
| 1000 |
90 |
| 1250 |
112 |
| 1500/1600 |
125 | |
| 用于变压器特殊情况的选用及用于其他电力设备配合的选用可与制造厂联系 |
 |
| 图1 BDG、BFG、AKG时间-电流特性 |
 |
| 图2 BDG、BFG、AKG限流特性 |
 |
| 图3 BDG、BFG、ALG l2t特性 |
| Type |
A |
B |
C |
φD |
| ADFHC |
356 |
314 |
254 |
51 |
| ADGHC |
461 |
419 |
359 |
51 |
| BDGHC |
461 |
419 |
359 |
51 |
| AFFHD |
356 |
314 |
254 |
76 |
| BFGHD |
461 |
419 |
359 |
76 |
| A(B)KGHD |
461 |
419 |
359 |
76 | |
 |
| Type |
A |
B |
C |
φD |
| ADFHF |
356 |
314 |
254 |
51 |
| ADGHF |
461 |
419 |
359 |
51 |
| BDGHF |
461 |
419 |
359 |
76 |
| AFFHF |
356 |
314 |
254 |
51 |
| BFGHF |
461 |
419 |
359 |
76 |
| A(B)KGHF |
461 |
419 |
359 |
76 | |
 |
| Type |
C |
φD |
| ADFHA |
254 |
51 |
| ADGHA |
359 |
51 |
| BDGHA |
359 |
51 |
| AFFHA |
254 |
76 |
| BFGHA |
359 |
76 |
| A(B)KGHA |
359 |
76 | |
 |
 |
 |
|
|
|